产品中心
- 泽任订制
- FST动物实验器械
- 瑞士ideal-tek镊子
- 瑞士Dumont镊子
- Techni-Tool
- 瑞士Rubis镊子
- arosurgica
- Genesee Scientific
- Gilder Grids
-
Entegris
- WEICON
- ACCURIS
- AIMS
- RMC钻石刀
- Sipel镊子
- 德国WIHA
-
Si-Mat
- Jokari
- Circuitmedic
-
Glissando病理切片扫描仪
- KNIPEX(凯尼派克)
- Swann-morton
- Cellpoint Scientific
- Swanstrom
- All-spec
- 新华器械
- Excelta
- MENDA
- MEISEI
- Erem
- Regine
-
OPTRASCAN病理扫描仪
- Benchmark
-
IDEAL
- 大龙仪器
- 五洋医疗
- Hozan(宝山)
- 3M
- Stoelting
- Roboz
-
Diatome钻石刀
- Fine Science Tools
- PLATO
-
抗原检测
- NanoSoft
-
Avantama
-
PSI打击器及配件
- Aptum
- xuron
- SPI
- ASI Instruments
-
上海一恒
-
上海雷磁
- Quantifoil
- 上海方需
- 苏州六六
-
Hamilton
- ISMART
-
显微镜
-
Bonllmann
- AVEN
- 塔望科技
-
瑞典Haglof激光测距仪
- STILLE
-
美国安维迪
- 德国贝朗蛇牌
- Medline
-
蛋白纯化系统
-
OHAUS奥豪斯
- 康博特森
- Ossila
- 赛宁(苏州)生物
- Bernstein
- 洁盟清洗机
- Ted Pella
- DSI
- Keller
-
Smart Tweezers
- 瑞士PB
-
Microscopes Internat...
- Lattice Gear
-
凯氏定氮仪
- lindstrom
- 美国EMS
-
1-material
-
仪器
- realisticflies
- Boive
- Zivic
产品详情
简单介绍:
SPI经销商、原装进口、质量保证、任何产品问题请联系我司销售。
详情介绍:
Oerlikon Leybold Scroll Pump 110-230 Volt AC, 50/60 Hz Single Phase
Many labs today are moving towards an oil free environment. This move has a number of strong supporters such as preventing backstreaming of oil into equipment, odors from the pump oil and well as the oil change and disposal of used oil itself. While there will always be the need for two stage mechanical pumps, some areas see an advantage of using a Scroll Pump.
The dry compressing of a Leybold SCROLLVAC SC-D pump operates on the principle of Archimedes spirals engaging each other. The vacuum is then created by reduction in volume of the trapped environment and compression of gases to a gas outlet.. SCROLLVAC pumps operate absolutely oil-free with a high effective pumping speed.
Of course, two stage mechanical pumps are less expensive and generally quieter in operation, but for those seeking an oil free lab, these pumps may be considered.
Technical Data
Nominal pumping speed
50 Hz m3/h (cfm) 15.0 (8.8)
60 Hz m3/h (cfm) 18.0 (10.6)
Pumping speed
50 Hz m3/h (cfm) 13.0 (7.7)
60 Hz m3/h (cfm) 15.5 (9.1)
Attainable ultimate pressure mbar (Torr) ≤ 0.016 (≤ 0.012)
Connections
Inlet DN 25
Exhaust DN 16
Noise level at 1 m, free field measurement dB(A) ≤ 58
Dimensions (W x H x D) mm (in.) 400 x 252 x 336
(15.75 x 9.92 x 13.23)
Weight Single-phase motor kg (lbs) Three-phase motor kg (lbs) 25 (55.2)
23 (50.8)
Many labs today are moving towards an oil free environment. This move has a number of strong supporters such as preventing backstreaming of oil into equipment, odors from the pump oil and well as the oil change and disposal of used oil itself. While there will always be the need for two stage mechanical pumps, some areas see an advantage of using a Scroll Pump.
The dry compressing of a Leybold SCROLLVAC SC-D pump operates on the principle of Archimedes spirals engaging each other. The vacuum is then created by reduction in volume of the trapped environment and compression of gases to a gas outlet.. SCROLLVAC pumps operate absolutely oil-free with a high effective pumping speed.
Of course, two stage mechanical pumps are less expensive and generally quieter in operation, but for those seeking an oil free lab, these pumps may be considered.
Technical Data
Nominal pumping speed
50 Hz m3/h (cfm) 15.0 (8.8)
60 Hz m3/h (cfm) 18.0 (10.6)
Pumping speed
50 Hz m3/h (cfm) 13.0 (7.7)
60 Hz m3/h (cfm) 15.5 (9.1)
Attainable ultimate pressure mbar (Torr) ≤ 0.016 (≤ 0.012)
Connections
Inlet DN 25
Exhaust DN 16
Noise level at 1 m, free field measurement dB(A) ≤ 58
Dimensions (W x H x D) mm (in.) 400 x 252 x 336
(15.75 x 9.92 x 13.23)
Weight Single-phase motor kg (lbs) Three-phase motor kg (lbs) 25 (55.2)
23 (50.8)
The SC 15D is suggested for use with the SPI Supplies Vacu Prep II. It can also be used on the SPI Supplies Sputter/Carbon Coater Systems. It should not be used on the Osmium Coater.